Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/17998
Full metadata record
DC FieldValueLanguage
dc.contributor.authorZennaro, M-
dc.contributor.authorO'Boy, DJ-
dc.contributor.authorLowe, PS-
dc.contributor.authorGan, T-H-
dc.date.accessioned2019-05-02T16:02:18Z-
dc.date.available2019-04-18-
dc.date.available2019-05-02T16:02:18Z-
dc.date.issued2019-
dc.identifier.citationSensors (Basel, Switzerland), 2019, 19 (8), 1848 (17 pp.)en_US
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/17998-
dc.description.abstractThickness-shear transducers for guided wave testing have been used in industry for over two decades and much research has been conducted to improve the resolution and sensitivity. Due to a geometric feature of the current state-of-the art transducer, there is an out-of-plane component in the propagation direction of the fundamental shear horizontal mode which complicates the signal interpretation. In such case, complex signal processing techniques need to be used for mode discrimination to assess the structural health with higher precision. Therefore, it is important to revise the transducer design to eliminate the out-of-plane components in the propagation direction of fundamental shear horizontal mode. This will enhance the mode purity of fundamental shear horizontal mode for its application in guided wave inspection. A numerical investigation has been conducted on a 3 mm thick 2 m circular steel plate to understand the behaviour and the characteristics of the state-of-the-art thickness-shear transducer. Based on the results, it is noted that the redesigning the electrode arrangement will suppress the out-of-plane components on the propagation direction of the fundamental shear horizontal mode. With the aid of this information current state-of-the-art transducers were redesigned and tested in laboratory conditions using the 3D Laser Doppler Vibrometer. This information will aid future transducer designers improve the resolution of thickness-shear transducers for guided wave applications and reduce the weight and cost of transducer array by eliminating the need of additional transducers to suppress spurious modes.en_US
dc.description.sponsorshipThis research was funded by Lloyd’s Registered Foundation and Loughborough University, grant number [30335], and the APC was funded by Loughborough University and Brunel Innovation Centre.en_US
dc.formatElectronic-
dc.languageeng-
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.subjectultrasonic guided waves testingen_US
dc.subjectmode purityen_US
dc.subjectnon-destructive testingen_US
dc.subjectnumerical simulations; sensor developmenten_US
dc.subjectthickness-shear transducersen_US
dc.titleCharacterization and Design Improvement of a Thickness-Shear Lead Zirconate Titanate Transducer for Low Frequency Ultrasonic Guided Wave Applications.en_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.3390/s19081848-
dc.relation.isPartOfSensors (Basel, Switzerland)-
pubs.issue8-
pubs.publication-statusPublished-
pubs.volume19-
dc.identifier.eissn1424-8220-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf6 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.