Title: Thermal Analysis of Horizontal Earth-Air Heat Exchangers in A Subtropical Climate: An Experimental Study
Authors: Lattieff, F
Atiya, MA
Lateef, RA
Jweeg, MJ
Abed, AM
Mahdi, JM
Talebizadehsardari, P
Keywords: geothermal energy,;sandy soil;earth-air heat exchangers;subtropical climate conditions;thermal;analyses
Issue Date: 2-Sep-2022
Publisher: Frontiers SA
Citation: Lattieff, F.A., Atiya, M.A., Lateef, R.A., Dulaimi, A., Jweeg, M.J., Abed, A.M., Mahdi, J.M. and Talebizadehsardari, P. (2022) 'Thermal analysis of horizontal earth-air heat exchangers in a subtropical climate: An experimental study', Frontiers in Built Environment, 8, 981946, pp. 1 - 13. doi: 10.3389/fbuil.2022.981946.
Abstract: Copyright © 2022 Lattieff, Atiya, Lateef, Dulaimi, Jweeg, Abed, Mahdi and Talebizadehsardari. The earth-air heat exchanger (EHX) has a promising potential to passively save the energy consumption of traditional air conditioning systems while maintaining a high degree of indoor comfort. The use of EHX systems for air conditioning in commercial and industrial settings offers several environmental benefits and is capable of operating in both standalone and hybrid modes. This study tests the performance and effectiveness of an EHX design in a sandy soil area in Baghdad, Iraq. The area has a climate of the subtropical semi-humid type. Ambient air temperatures and soil temperatures were recorded throughout the months of 2021. During the months of January and June, the temperatures of the inlet and outflow air at varying air velocities were monitored concurrently in 10-min increments at each location. Further numerical and thermodynamical analyses of the measurements were conducted to reveal the influencing performance parameters. The highest temperature rises of air between the input and exit sections were determined as 12.3°C (January) and 17.2°C (June). It is found that the maximum values of effectiveness are 0.80 and 0.81, while coefficients of performance are 1.6 and 1.8 for January and June, respectively. It is also found that the EHX shows good functionality and effectiveness, with potential energy savings for equipment for cooling and heating under different weather conditions.
Description: Data availability statement: The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.
URI: https://bura.brunel.ac.uk/handle/2438/25240
DOI: https://doi.org/10.3389/fbuil.2022.981946
Other Identifiers: 981946
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © 2022 Lattieff, Atiya, Lateef, Dulaimi, Jweeg, Abed, Mahdi and Talebizadehsardari. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.2.81 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons