Please use this identifier to cite or link to this item:
http://bura.brunel.ac.uk/handle/2438/26766
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Poškas, R | - |
dc.contributor.author | Sirvydas, A | - |
dc.contributor.author | Kulkovas, V | - |
dc.contributor.author | Jouhara, H | - |
dc.contributor.author | Poškas, P | - |
dc.contributor.author | Miliauskas, G | - |
dc.contributor.author | Puida, E | - |
dc.date.accessioned | 2023-07-02T09:33:49Z | - |
dc.date.available | 2023-07-02T09:33:49Z | - |
dc.date.issued | 2021-07-29 | - |
dc.identifier | ORCID iD: Hussam Jouhara https://orcid.org/0000-0002-6910-6116 | - |
dc.identifier | 1310 | - |
dc.identifier.citation | Poškas, R. et al. (2021) 'An experimental investigation of water vapor condensation from biofuel flue gas in a model of condenser, (2) local heat transfer in a calorimetric tube with water injection', Processes, 9 (8), 1310, pp. 1 - 18. doi: 10.3390/pr9081310. | en_US |
dc.identifier.uri | https://bura.brunel.ac.uk/handle/2438/26766 | - |
dc.description | Data Availability Statement: Not applicable. | en_US |
dc.description.abstract | Copyright © 2021 by the authors. In order for the operation of the condensing heat exchanger to be efficient, the flue gas temperature at the inlet to the heat exchanger should be reduced so that condensation can start from the very beginning of the exchanger. A possible way to reduce the flue gas temperature is the injection of water into the flue gas flow. Injected water additionally moistens the flue gas and increases its level of humidity. Therefore, more favorable conditions are created for condensation and heat transfer. The results presented in the second paper of the series on condensation heat transfer indicate that water injection into the flue gas flow drastically changes the distribution of temperatures along the heat exchanger and enhances local total heat transfer. The injected water causes an increase in the local total heat transfer by at least two times in comparison with the case when no water is injected. Different temperatures of injected water mainly have a major impact on the local total heat transfer until almost the middle of the model of the condensing heat exchanger. From the middle part until the end, the heat transfer is almost the same at different injected water temperatures. | en_US |
dc.description.sponsorship | Research Council of Lithuania (LMTLT), grant number S-MIP-20-30. | en_US |
dc.format.extent | 1 - 18 | - |
dc.format.medium | Electronic | - |
dc.language | English | - |
dc.language.iso | en_US | en_US |
dc.publisher | MDPI | en_US |
dc.rights | Copyright © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). | - |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | - |
dc.subject | biofuel flue gas | en_US |
dc.subject | water vapor condensation | en_US |
dc.subject | vertical tube | en_US |
dc.subject | experiments | en_US |
dc.subject | water injection | en_US |
dc.subject | total local heat transfer | en_US |
dc.subject | condensation efficiency | en_US |
dc.title | An experimental investigation of water vapor condensation from biofuel flue gas in a model of condenser, (2) local heat transfer in a calorimetric tube with water injection | en_US |
dc.type | Article | en_US |
dc.identifier.doi | https://doi.org/10.3390/pr9081310 | - |
dc.relation.isPartOf | Processes | - |
pubs.issue | 8 | - |
pubs.publication-status | Published | - |
pubs.volume | 9 | - |
dc.identifier.eissn | 2227-9717 | - |
dc.rights.holder | The authors | - |
Appears in Collections: | Dept of Mechanical and Aerospace Engineering Research Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
FullText.pdf | Copyright © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). | 3.27 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License