Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/26766
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPoškas, R-
dc.contributor.authorSirvydas, A-
dc.contributor.authorKulkovas, V-
dc.contributor.authorJouhara, H-
dc.contributor.authorPoškas, P-
dc.contributor.authorMiliauskas, G-
dc.contributor.authorPuida, E-
dc.date.accessioned2023-07-02T09:33:49Z-
dc.date.available2023-07-02T09:33:49Z-
dc.date.issued2021-07-29-
dc.identifierORCID iD: Hussam Jouhara https://orcid.org/0000-0002-6910-6116-
dc.identifier1310-
dc.identifier.citationPoškas, R. et al. (2021) 'An experimental investigation of water vapor condensation from biofuel flue gas in a model of condenser, (2) local heat transfer in a calorimetric tube with water injection', Processes, 9 (8), 1310, pp. 1 - 18. doi: 10.3390/pr9081310.en_US
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/26766-
dc.descriptionData Availability Statement: Not applicable.en_US
dc.description.abstractCopyright © 2021 by the authors. In order for the operation of the condensing heat exchanger to be efficient, the flue gas temperature at the inlet to the heat exchanger should be reduced so that condensation can start from the very beginning of the exchanger. A possible way to reduce the flue gas temperature is the injection of water into the flue gas flow. Injected water additionally moistens the flue gas and increases its level of humidity. Therefore, more favorable conditions are created for condensation and heat transfer. The results presented in the second paper of the series on condensation heat transfer indicate that water injection into the flue gas flow drastically changes the distribution of temperatures along the heat exchanger and enhances local total heat transfer. The injected water causes an increase in the local total heat transfer by at least two times in comparison with the case when no water is injected. Different temperatures of injected water mainly have a major impact on the local total heat transfer until almost the middle of the model of the condensing heat exchanger. From the middle part until the end, the heat transfer is almost the same at different injected water temperatures.en_US
dc.description.sponsorshipResearch Council of Lithuania (LMTLT), grant number S-MIP-20-30.en_US
dc.format.extent1 - 18-
dc.format.mediumElectronic-
dc.languageEnglish-
dc.language.isoen_USen_US
dc.publisherMDPIen_US
dc.rightsCopyright © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectbiofuel flue gasen_US
dc.subjectwater vapor condensationen_US
dc.subjectvertical tubeen_US
dc.subjectexperimentsen_US
dc.subjectwater injectionen_US
dc.subjecttotal local heat transferen_US
dc.subjectcondensation efficiencyen_US
dc.titleAn experimental investigation of water vapor condensation from biofuel flue gas in a model of condenser, (2) local heat transfer in a calorimetric tube with water injectionen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.3390/pr9081310-
dc.relation.isPartOfProcesses-
pubs.issue8-
pubs.publication-statusPublished-
pubs.volume9-
dc.identifier.eissn2227-9717-
dc.rights.holderThe authors-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).3.27 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons