Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/8633
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGiridharan, R-
dc.date.accessioned2014-07-14T10:31:19Z-
dc.date.available2014-07-14T10:31:19Z-
dc.date.issued2008-
dc.identifier.citationSolar Energy, 82(11), 986-998, 2008en_US
dc.identifier.issn0038-092X-
dc.identifier.urihttp://www.sciencedirect.com/science/article/pii/S0038092X08001084en
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/8633-
dc.descriptionThis is the post-print version of the final paper published in Solar Energy. The published article is available from the link below. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. Copyright @ 2008 Elsevier B.V.en_US
dc.description.abstractThe study looks at the potential of physical characteristics in mitigating the urban heat island intensity (UHI) in London during summer. This research uses six on-site variables namely aspect ratio, surface albedo, plan density ratio, green density ratio, fabric density ratio and thermal mass for the investigation in six data sets. The climatic variations in summer are controlled by classifying the data into clear sky, partially cloudy and cloudy periods. Geographical variation is controlled by classifying the data into core, urban and semi urban areas. Maximum daytime UHI of 8.9 °C is found in semi-urban area during partially cloudy period while maximum nocturnal UHI of 8.6 °C is found in urban area during clear sky period when the wind velocity is below 5 m/s. The most critical climate and geographical location in determining the changes in outdoor air temperature in London are partially cloudy periods and urban areas respectively. Among the variables studied, most critical variable that determines the daytime and nocturnal changes in outdoor air temperature is surface albedo.en_US
dc.description.sponsorshipEPSCRen_US
dc.languageEnglish-
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectUrban heat island intensity (UHI)en_US
dc.subjectSky cloud conditionsen_US
dc.subjectCoreen_US
dc.subjectUrbanen_US
dc.subjectSemi-urbanen_US
dc.subjectOn-site variablesen_US
dc.titleUrban heat island intensity in London: An investigation of the impact of physical characteristics on changes in outdoor air temperature during summeren_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.1016/j.solener.2008.05.004-
pubs.organisational-data/Brunel-
pubs.organisational-data/Brunel/Administration and Support Staff-
pubs.organisational-data/Brunel/Administration and Support Staff/Administration and Support Staff-
pubs.organisational-data/Brunel/Brunel Active Staff TxP-
pubs.organisational-data/Brunel/Brunel Active Staff TxP/College of Engineering, Design and Physical Sciences-
pubs.organisational-data/Brunel/Brunel Active Staff TxP/College of Engineering, Design and Physical Sciences/Dept of Mechanical, Aerospace and Civil Engineering-
pubs.organisational-data/Brunel/Leavers-
pubs.organisational-data/Brunel/University Research Centres and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/Brunel Business School - URCs and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/Brunel Business School - URCs and Groups/Centre for Research into Entrepreneurship, International Business and Innovation in Emerging Markets-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Arts - URCs and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Arts - URCs and Groups/Brunel Centre for Contemporary Writing-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Engineering and Design - URCs and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Engineering and Design - URCs and Groups/Centre for Energy and Built Environment Research-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Health Sciences and Social Care - URCs and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Health Sciences and Social Care - URCs and Groups/Brunel Institute for Ageing Studies-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Health Sciences and Social Care - URCs and Groups/Brunel Institute of Cancer Genetics and Pharmacogenomics-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Health Sciences and Social Care - URCs and Groups/Centre for Systems and Synthetic Biology-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Information Systems, Computing and Mathematics - URCs and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Information Systems, Computing and Mathematics - URCs and Groups/Multidisclipary Assessment of Technology Centre for Healthcare (MATCH)-
Appears in Collections:Mechanical and Aerospace Engineering
Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
Fulltext.pdf456.3 kBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.