Abstract: | Power factor is a significant element in power systems which is defined as the angle difference between voltages and currents that produces power fluctuation between sources and loads. Since, 40-50% of consumption of electrical power in industry is induction machines which are inductive loads, monitoring of the power factor is necessary in order to protect systems. To monitor the power factor on induction machines, it would require both voltage and current waveforms measurement in order to apply the displacement method which require equipments. In this paper, we present a mathematical method using Kriging to determine the operating power factor for an induction machine. Estimation of the operating power factor would be effectively implemented for under load detection and compensation for improving the power quality. Experimental results will be indicated to substantiate the feasibility of the proposed methods. |
URI: | http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7339877 http://bura.brunel.ac.uk/handle/2438/11716 |
DOI: | http://dx.doi.org/10.1109/UPEC.2015.7339877 |
Appears in Collections: | Dept of Electronic and Electrical Engineering Research Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Fulltext.pdf | 445.45 kB | Adobe PDF | View/Open |
Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.