Please use this identifier to cite or link to this item:
http://bura.brunel.ac.uk/handle/2438/22773
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wu, R | - |
dc.contributor.author | Wang, D | - |
dc.contributor.author | Xie, C | - |
dc.contributor.author | Lai, CS | - |
dc.contributor.author | Huang, J | - |
dc.contributor.author | Lai, LL | - |
dc.date.accessioned | 2021-05-26T20:18:13Z | - |
dc.date.available | 2021-03-25 | - |
dc.date.available | 2021-05-26T20:18:13Z | - |
dc.date.issued | 2021-03-25 | - |
dc.identifier.citation | Wu, R., Wang, D., Xie, C., Lai, C.S., Huang, J. and Lai, L.L. (2021) 'Distributed Control Method for Air-conditioning Load Participating in Voltage Management of Distribution Network', Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (6), pp. 215 - 222. doi: 10.7500/AEPS20200512006. | en_US |
dc.identifier.issn | 1000-1026 | - |
dc.identifier.uri | https://bura.brunel.ac.uk/handle/2438/22773 | - |
dc.description.abstract | Copyright © 2021 The Authors. The scale of air-conditioning load in the distribution network is rapidly increasing with the improvement of living level. Furthermore, the buildings equipped with air conditioners have the capability of thermal buffer, which makes it valuable for participating in demand-side response. In the meanwhile, the penetration rate of distributed photovoltaic (PV) power generation in the distribution network is gradually increasing. The fluctuations of PV power generation have a negative impact on the voltage stability of the distribution network. This paper proposes a distributed consensus-driven control method. The aggregated air-conditioning load is scheduled to participate in the voltage management of the distribution network through the limited communication links established between the aggregators. A two-dimensional thermal parameter model is adopted to calculate the thermal exchange of the buildings equipped with air conditioners more accurately to guarantee the thermal comfort requirement of users. Finally, the case studies are performed on a modified IEEE 15-bus distribution network to verify the effectiveness and robustness of the proposed control strategy. | en_US |
dc.format.extent | 215 - 222 | - |
dc.format.medium | Print-Electronic | - |
dc.language.iso | zh | en_US |
dc.publisher | Dianli Xitong Zidonghua | en_US |
dc.subject | air-conditioning load | en_US |
dc.subject | distributed control | en_US |
dc.subject | voltage management | en_US |
dc.subject | distributed photovoltaic (PV) power generation | en_US |
dc.subject | active distribution network | en_US |
dc.title | Distributed Control Method for Air-conditioning Load Participating in Voltage Management of Distribution Network | en_US |
dc.type | Article | en_US |
dc.identifier.doi | https://doi.org/10.7500/AEPS20200512006 | - |
dc.relation.isPartOf | Dianli Xitong Zidonghua/Automation of Electric Power Systems | - |
pubs.issue | 6 | - |
pubs.publication-status | Published | - |
pubs.volume | 45 | - |
Appears in Collections: | Dept of Electronic and Electrical Engineering Research Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
FullText.pdf | 1.3 MB | Adobe PDF | View/Open |
Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.