Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/23514
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbo-Hamad, GM-
dc.contributor.authorIbrahim, DK-
dc.contributor.authorAboul Zahab, E-
dc.contributor.authorZobaa, AF-
dc.date.accessioned2021-11-14T15:35:18Z-
dc.date.available2021-11-14T15:35:18Z-
dc.date.issued2021-10-28-
dc.identifier7074-
dc.identifier.citationAbo-Hamad, G. M., Ibrahim, D. K., Aboul Zahab, E. and Zobaa, A. F. (2021) ‘Dynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC’, Energies, 14(21), 7074, pp. 1-23. doi: 10.3390/en14217074.en_US
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/23514-
dc.description.abstractCopyright: © 2021 by the authors. A two-fold adaptive dynamic quadrilateral relay is developed in this research for protecting Thyristor-Controlled Series Compensator (TCSC)-compensated transmission lines (TLs). By investigating a new tilt angle and modifying the Takagi method to recognize the fault zone identifier, the proposed relay adapts its reactive reach and resistive reach separately and independently. The investigated tilt angle and identified fault zone use the TCSC reactance to compensate its effect on the TL parameters and system homogeneity. Excessive tests are simulated by MATLAB on the non-homogenous network, IEEE-9 bus system and further tests are carried out on IEEE-39 bus system in order to generalize and validate the efficiency of the proposed approach. The designed trip boundaries are able to detect wide range of resistive faults under all TCSC modes of operations. The proposed approach is easy to implement as there no need for data synchronization or a high level of computation and filtration. Moreover, the proposed adaptive dynamic relay can be applied for non-homogeneity systems and short as well as long TLs which are either TCSC-compensated or -uncompensated TLs.en_US
dc.format.extent1 - 23-
dc.language.isoen_USen_US
dc.publisherMDPIen_US
dc.rightsCopyright: © 2021 by the authors.Licensee MDPI, Basel, Switzerland. This is an open access article distributed under the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectdistance relayen_US
dc.subjectfault resistanceen_US
dc.subjectquadrilateral characteristicen_US
dc.subjectresistance and reactance elementsen_US
dc.subjectThyristor Controlled Series Compensator (TCSC)en_US
dc.titleDynamic quadrilateral characteristic based distance relays for transmission lines equipped with TCSCen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.3390/en14217074-
dc.relation.isPartOfEnergies-
pubs.issue21-
pubs.publication-statusPublished-
pubs.volume14-
dc.identifier.eissn1996-1073-
Appears in Collections:Dept of Electronic and Electrical Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf17.08 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons