Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/25155
Full metadata record
DC FieldValueLanguage
dc.contributor.authorImris, P-
dc.contributor.authorTaylor, GA-
dc.contributor.authorBradley, ME-
dc.contributor.authorLi, Y-
dc.date.accessioned2022-09-06T10:42:05Z-
dc.date.available2022-09-06T10:42:05Z-
dc.date.issued2022-09-01-
dc.identifier6386-
dc.identifier.citationImris, P. et al. (2022) 'A Novel Hardware-in-the-Loop Approach to Investigate the Impact of Low System Inertia on RoCoF Relay Settings', Energies, 15 (17), 6386, pp. 1 - 23. doi: 10.3390/en15176386.en_US
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/25155-
dc.description.abstractCopyright: © 2022 by the authors. This paper presents a novel hardware-in-the-loop (HIL) approach as used to investigate the impact of the reduction in inertia on the Great Britain (GB) electrical power system with regard to rate of change of frequency (RoCoF) settings for Loss-of-Mains (LoM) protection. Furthermore, the research as presented in this paper updates, enhances, and validates a reduced model of the Great Britain transmission system, as originally developed in DIgSILENT PowerFactory by the National Grid Electricity System Operator. The enhanced model has been developed for integrated use with the OPAL-RT real-time HIL simulation toolkit and is validated against phasor measurement unit (PMU) data from actual disturbance events using novel automated interfacing between both integrated simulation platforms, PowerFactory from DIgSILENT and ePHASORSIM from OPAL-RT. The corresponding simulations show that the updated reduced model is capable of capturing the dynamic behaviour of the GB transmission system, including both local and inter-area oscillations, with satisfactory accuracy. Finally, the paper presents HIL study results with the reduced model to investigate the influence of decreasing system inertia on the response of LoM protection relays. The studies show that decreasing system inertia may have a significant impact on LoM relays using RoCoF detection, particularly relays using the legacy G59 setting of 0.125 Hz/s. Initial studies have also demonstrated the potential for a previously unrecognised interaction between system oscillations and the 500 ms operating delay, as specified in G59 and G99 Engineering Recommendations. Consequently, faster local oscillations (>1 Hz) reset the relay and decrease the sensitivity, whereas slower inter-area oscillations (<1 Hz) appear to cause the relay to overestimate the average RoCoF.en_US
dc.description.sponsorshipNational Grid Electricity System Operator with Network Innovation Allowance funding from OFGEM (Office of Gas and Electricity Markets).en_US
dc.format.extent1 - 23-
dc.format.mediumElectronic-
dc.languageEnglish-
dc.language.isoen_USen_US
dc.publisherMDPI AGen_US
dc.rightsCopyright: © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This is an open access article distributed under the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectrate of change of frequencyen_US
dc.subjectloss of mainsen_US
dc.subjectsystem inertiaen_US
dc.subjectreduced modelen_US
dc.subjecthardware-in-the-loopen_US
dc.titleA Novel Hardware-in-the-Loop Approach to Investigate the Impact of Low System Inertia on RoCoF Relay Settingsen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.3390/en15176386-
dc.relation.isPartOfEnergies-
pubs.issue17-
pubs.publication-statusPublished online-
pubs.volume15-
dc.identifier.eissn1996-1073-
dc.rights.holderThe authors-
Appears in Collections:Dept of Electronic and Electrical Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf8.14 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons