Please use this identifier to cite or link to this item:
http://bura.brunel.ac.uk/handle/2438/28800
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gunaratna Mudiyanselage, NH | - |
dc.contributor.author | Hobson, P | - |
dc.contributor.author | Smith, D | - |
dc.coverage.spatial | Milan, Italy | - |
dc.date.accessioned | 2024-04-18T15:00:38Z | - |
dc.date.available | 2024-04-18T15:00:38Z | - |
dc.date.issued | 2022-11-07 | - |
dc.identifier | ORCiD: Peter R. Hobson https://orcid.org/0000-0002-5645-5253 | - |
dc.identifier | ORCiD: David R. Smith https://orcid.org/0000-0003-3658-4506 | - |
dc.identifier.citation | Gunaratna Mudiyanselage, N.H., Hobson. P.R. and Smith, D.R. (2022) Determination of energy resolution for YSO:Ce detector modelled with FLUKA code [Poster]. Exhibited at 2022 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 7 November. 60cm x 84 cm. | en_US |
dc.identifier.uri | https://bura.brunel.ac.uk/handle/2438/28800 | - |
dc.description | Conference poster presented at 2022 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Milan, Italy, 7 November, 2022. | en_US |
dc.description.abstract | Conclusion: In this study, a 5 x 5 x 5 mm 3 YSO Ce detector was modelled using the FLUKA code The pulse height distributions of the detector were obtained for each point gamma source in the energy range 59 keV 662 keV, and the energy resolution was calculated It was observed that relative percentage differences between the experimental and simulation results are within 10 This study showed that the FLUKA code also can be used to determine the energy resolution and can therefore be of benefit in terms of reducing financial cost and time in the development of new scintillators and radiation sensors. | en_US |
dc.description.sponsorship | This work was performed as a part of Ph.D. project funded under EPSRC DTP grant EP/T518116/1. The authors would like to thank EPSRC for financial support, and Brunel University London for facilitating this research. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | IEEE | en_US |
dc.source | 2022 IEEE Nuclear Science Symposium and Medical Imaging Conference | - |
dc.source | 2022 IEEE Nuclear Science Symposium and Medical Imaging Conference | - |
dc.title | Determination of energy resolution for YSO:Ce detector modelled with FLUKA code | en_US |
dc.type | Other | en_US |
pubs.finish-date | 2022-11-07 | - |
pubs.start-date | 2022-11-07 | - |
Appears in Collections: | Dept of Electronic and Electrical Engineering Research Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Poster.pdf | 354.23 kB | Adobe PDF | View/Open |
Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.