Please use this identifier to cite or link to this item: https://bura.brunel.ac.uk/handle/2438/34181
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSommerville, Stephen-
dc.contributor.authorAunedi, Marko-
dc.contributor.authorTaylor, Gareth A-
dc.coverage.spatialLondon, UK-
dc.date.accessioned2026-11-15T18:33:29Z-
dc.date.available2026-11-15T18:33:29Z-
dc.date.issued2025-09-02-
dc.identifier.citationSommerville, S., Aunedi, M. and Taylor, G.A. (2025) 'Challenges of Fault Current Analysis using IEC 60909 and ENA G74 in Grids Dominated by Converter Fed Generation', 60th International Universities Power Engineering Conference (UPEC), London, UK, 2–5 September, pp. 1–6. doi: 10.1109/upec65436.2025.11279755.en_US
dc.identifier.isbn9798331565206-
dc.identifier.isbn9798331565213-
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/34181-
dc.description.abstractFault current analysis is a key part of designing, managing and analysing an electrical network. The traditional IEC 60909 calculation method has been well established in standards for many decades, however it is based on a number of simplified assumptions to make the computational process simple and efficient. A comparison is also included with the ENA G74 short circuit calculation method. The assumptions used in these methods are creating misleading results in large renewable energy generation plants that have a significant portion of Converter Fed Generation (CFG), by overstating the retained voltages and increasing the calculated fault levels. This paper shows how these assumptions break down in generation sites dominated by CFG, and can produce unrealistic results, due to the constant current output of the CFG. The paper also outlines some of the shortfalls in assessment of Grid Forming Inverters fault contribution.en_US
dc.format.extentpp. 1–6-
dc.format.mediumPrint-Electronic-
dc.languageEnglishen_US
dc.language.isoen_USen_US
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)en_US
dc.rightsRe-use licence for this version: Creative Commons Attribution 4.0 International-
dc.rightsLicence for published version: Publisher's own licence-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.source60th International Universities Power Engineering Conference (UPEC)en_US
dc.subjectENA G74en_US
dc.subjectfault current analysisen_US
dc.subjectgrid following inverteren_US
dc.subjectgrid forming inverter and IEC 60909en_US
dc.titleChallenges of Fault Current Analysis using IEC 60909 and ENA G74 in Grids Dominated by Converter Fed Generationen_US
dc.typeConference paperen_US
dc.date.dateAccepted2025-06-30-
dc.identifier.doihttps://doi.org/10.1109/upec65436.2025.11279755-
dc.relation.isPartOf2025 60th International Universities Power Engineering Conference (UPEC)en_US
pubs.finish-date2025-09-05-
pubs.publication-statusPublished-
pubs.start-date2025-09-02-
dc.rights.licensehttps://creativecommons.org/licenses/by/4.0/legalcode.en-
dcterms.dateAccepted2025-06-30-
dcterms.issued2025-09-02-
dc.date.updated2026-11-15T18:22:48Z-
dc.rights.holderThe Authors-
dc.contributor.orcidAunedi, Marko [0000-0002-8195-7941]-
dc.contributor.orcidTaylor, Gareth [0000-0003-0867-2365]-
Appears in Collections:Department of Electronic and Electrical Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright ‘For the purpose of open access, the author has applied a ‘Creative Commons Attribution (CC BY) licence to any Author Accepted Manuscript version arising.’1.05 MBAdobe PDFView/Open