Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/9282
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTseluiko, D-
dc.contributor.authorBlyth, MG-
dc.contributor.authorPapageorgiou, D-
dc.contributor.author4th Micro and Nano Flows Conference (MNF2014)-
dc.date.accessioned2014-12-02T14:00:35Z-
dc.date.available2014-12-02T14:00:35Z-
dc.date.issued2014-
dc.identifier.citation4th Micro and Nano Flows Conference, University College London, UK, 7-10 September 2014, Editors CS König, TG Karayiannis and S. Balabanien_US
dc.identifier.isbn978-1-908549-16-7-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/9282-
dc.descriptionThis paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.en_US
dc.description.abstractAbsolute and convective instabilities in a non-local model that arises in the analysis of thin-film flows over flat or corrugated walls in the presence of an applied electric field are discussed. Electrified liquid films arise, for example, in coating processes where liquid films are deposited onto a target surfaces with a view to producing an evenly coating layer. In practice, the target surface, or substrate, may be irregular in shape and feature corrugations or indentations. This may lead to non-uniformities in the thickness of the coating layer. Attempts to mitigate film-surface irregularities can be made using, for example, electric fields. We analyse the stability of such thin-film flows and show that if the amplitude of the wall corrugations and/or the strength of the applied electric field is increased the convectively unstable flow undergoes a transition to an absolutely unstable flow.en_US
dc.language.isoenen_US
dc.publisherBrunel University Londonen_US
dc.relation.ispartofseriesID 7-
dc.subjectAbsolute/convective instabilityen_US
dc.subjectThin filmsen_US
dc.subjectBoundary integral methodsen_US
dc.subjectnon-local equationsen_US
dc.titleAbsolute and convective instabilities in non-local active-dissipative equations arising in the modelling of thin liquid filmsen_US
dc.typeConference Paperen_US
Appears in Collections:Brunel Institute for Bioengineering (BIB)
The Brunel Collection

Files in This Item:
File Description SizeFormat 
MNF2014_Full_Paper_Tseluiko_et_al_revised.pdf854.7 kBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.