Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/12222
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKotsovinos, P-
dc.contributor.authorUsmani, A-
dc.date.accessioned2016-03-02T10:19:03Z-
dc.date.available2013-07-
dc.date.available2016-03-02T10:19:03Z-
dc.date.issued2012-
dc.identifier.citationFire Technology, 49, (3): pp. 741 - 765, (2012)en_US
dc.identifier.issn0015-2684-
dc.identifier.issn1572-8099-
dc.identifier.urihttp://link.springer.com/article/10.1007%2Fs10694-012-0283-8-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/12222-
dc.description.abstractThe collapse of the World Trade Center buildings on September 11, 2001 posed questions on the stability of tall buildings in fire. Understanding the collapse of the WTC Towers offers the opportunity to learn useful engineering lessons in order to improve the design of future tall buildings against fire induced collapse. This paper extends previous research on the modelling of the collapse of the WTC Towers on September 11, 2001 using a newly developed ‘‘structures in fire’’ simulation capability in the open source software framework OpenSees. The simulations carried out are validated by comparisons with previous work and against the findings from the NIST investigation, albeit not in the forensic sense. The column ‘‘pull in’’ that triggers the instability of the structure and leads to collapse is explained. The collapse mechanisms of generic composite tall buildings are also examined. This is achieved through carrying out a detailed parametric study varying the relative stiffness of the column and the floors. The two main mechanisms identified in previous research (weak and strong floor) are reproduced and criteria are established on their occurrence. The analyses performed revealed that the collapse mechanism type depended on the bending stiffness ratio and the number of floors subjected to fire and that the most probable type of failure is the strong floor collapse. The knowledge of these mechanisms is of practical use if stakeholders wish to extend the tenability of a tall building structure in a major fire.en_US
dc.description.sponsorshipProfessor Jose Torero and the Open-Sees team at PEER, UC Berkeleyen_US
dc.format.extent741 - 765-
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.subjectStructures in fireen_US
dc.subjectProgressive collapseen_US
dc.subjectTall building collapse mechanismsen_US
dc.subjectWTC collapsesen_US
dc.subjectNonlinear dynamic thermo-mechanical analysis of structural framesen_US
dc.subjectOpenSeesen_US
dc.titleThe world trade center 9/11 disaster and progressive collapse of tall buildingsen_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.1007/s10694-012-0283-8-
dc.relation.isPartOfFire Technology-
pubs.issue3-
pubs.publication-statusPublished-
pubs.publication-statusPublished-
pubs.volume49-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
Fulltext.pdf1.38 MBUnknownView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.