Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/21455
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUsman, M-
dc.contributor.authorImran, M-
dc.contributor.authorHaglind, F-
dc.contributor.authorPesyridis, A-
dc.contributor.authorPark, B-S-
dc.date.accessioned2020-08-17T15:10:52Z-
dc.date.available2020-08-17T15:10:52Z-
dc.date.issued2020-08-17-
dc.identifier115889-
dc.identifier.citationUsman, M., Imran, M., Haglind, F., Pesyridis, A. and Park, B.-S. (2020) 'Experimental analysis of a micro-scale organic Rankine cycle system retrofitted to operate in grid-connected mode', Applied Thermal Engineering, 180, 115889, pp. 1 - 12 . doi: 10.1016/j.applthermaleng.2020.115889.-
dc.identifier.issn1359-4311-
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/21455-
dc.descriptionAppendix A. Supplementary material: Supplementary data to this article can be found online at https://doi.org/10.1016/j.applthermaleng.2020.115889.-
dc.description.abstractCopyright © 2020 The Authors. This work presents the retrofitting of a micro-scale organic Rankine cycle system originally designed for off-grid operation, modified to operate in grid-connected mode. Quantitative and qualitative performance comparisons of the grid-connected and off-grid connected organic Rankine cycle system are made based on experimental data of an organic Rankine cycle test rig. The operating strategies of the two systems are discussed in detail. The organic Rankine cycle test rig has a nominal power output of 1 kW with R245fa as the working fluid, a scroll expander as the expansion machine and steam as the heat source. Initially, the experiments were performed in off-grid operation mode with a self-excited alternating current generator. Subsequently, the organic Rankine cycle test rig was retrofitted for grid-connected mode, replacing the alternating current generator with an induction motor, regenerative variable frequency drive and grid connection. The rig modification was carefully done in such a way that the expander rotational speed was not fixed by the grid frequency, offering an additional control parameter for operational control optimisation. The modified system is able to supply 1.162 kW of gross electric power to the grid while a net electric output of 0.967 kW is measured. The same system is able to generate 1.016 kW (gross) and 0.838 kW (net) electric output in grid-connected mode. The net thermal-to-electric conversion efficiency at peak power generation is 7.36% and 4.66% in grid-connected and off-grid operating mode, respectively.-
dc.description.sponsorshipEuropean Union's Horizon 2020 research and innovation programme with two Marie Skłodowska-Curie Fellowships under grant agreement number 844023 (project SuperVGE) and 751947 (project DYNCON-ORC); Research and Development Program of the Korea Institute of Energy Research (B9-2451-6).en_US
dc.format.extent1 - 11-
dc.format.mediumPrint-Electronic-
dc.languageEnglish-
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.rightsCopyright © 2020 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/).-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectorganic Rankine cycleen_US
dc.subjectgrid-connected modeen_US
dc.subjectoff-grid modeen_US
dc.subjectR245faen_US
dc.subjectscroll expanderen_US
dc.subjectwaste heat recoveryen_US
dc.titleExperimental analysis of a micro-scale organic Rankine cycle system retrofitted to operate in grid-connected modeen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.1016/j.applthermaleng.2020.115889-
dc.relation.isPartOfApplied Thermal Engineering-
pubs.publication-statusPublished-
pubs.volume180-
dc.identifier.eissn1873-5606-
dc.rights.holderThe Authors-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf2.28 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons