Please use this identifier to cite or link to this item:
http://bura.brunel.ac.uk/handle/2438/26253
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jiang, P | - |
dc.contributor.author | Atherton, M | - |
dc.contributor.author | Millar, B | - |
dc.date.accessioned | 2023-04-06T10:27:51Z | - |
dc.date.available | 2023-04-06T10:27:51Z | - |
dc.date.issued | 2023-03-14 | - |
dc.identifier | ORCID iDs: Mark Atherton https://orcid.org/0000-0002-3293-4241; Pingfei Jiang https://orcid.org/0000-0001-6163-2632. | - |
dc.identifier.citation | Jiang, P., Atherton, M. and Millar, B. (2023) 'Dental drill noise reduction using a commercially available device', Primary dental journal, 12 (1), pp. 73 - 78 (6). doi: 10.1177/20501684231155962. | en_US |
dc.identifier.issn | 2050-1684 | - |
dc.identifier.uri | https://bura.brunel.ac.uk/handle/2438/26253 | - |
dc.description.abstract | Copyright © The Author(s) 2023. Aim:: The dental handpiece noise in a dental surgery is concerning to both patients and staff as a major cause of dental phobia in patients and potential hearing loss in clinical staff. High-frequency noise generated by dental handpieces is considered to be the worst of the many noises in a dental clinic. Methods to reduce this noise have been proposed and either passive or active noise reduction headphones are often suggested. However, in a dental surgery environment, the need for good verbal communication with the patient needs to be maintained. As a result, this paper aims to evaluate one proprietary anti-noise device considered suitable for this specific purpose. Methods: Lab-based experiments were set up and carried out to evaluate QuietOn, using GRAS 43AG-1 Ear and Cheek Simulator to mimic a section of the human head and ear to represent the acoustic characteristics of an actual ear. Two types of dental drill noise recordings, one for electric motor-driven and another one for air turbine-driven, were played back through high-definition speakers. Sound data captured by the simulator are then visualised and plotted using MATLAB for analysis. Main findings: QuietOn is effective at low frequencies (< 1kHz). However, when dealing with high-frequency noise such as dental handpieces it is ineffective yet subdues verbal communication. Conclusions: Further development of passive or active noise cancellation earplugs is still needed to target dental handpiece noise while maintaining verbal communication. | en_US |
dc.format.extent | 73 - 78 (6) | - |
dc.format.medium | Print-Electronic | - |
dc.language.iso | en_US | en_US |
dc.publisher | SAGE Publicaitons | en_US |
dc.rights | Copyright © The Author(s) 2023. Rights and permissions: Creative Commons License (CC BY 4.0). This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). | - |
dc.subject | passive noise reduction | en_US |
dc.subject | dental drill noise | en_US |
dc.subject | high-frequency noise | en_US |
dc.title | Dental drill noise reduction using a commercially available device | en_US |
dc.type | Article | en_US |
dc.identifier.doi | https://doi.org/10.1177/20501684231155962 | - |
dc.relation.isPartOf | Primary dental journal | - |
pubs.issue | 1 | - |
pubs.publication-status | Published | - |
pubs.volume | 12 | - |
dc.identifier.eissn | 2050-1692 | - |
Appears in Collections: | Dept of Mechanical and Aerospace Engineering Research Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
FullText.pdf | Copyright © The Author(s) 2023. Rights and permissions: Creative Commons License (CC BY 4.0). This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). | 2.04 MB | Adobe PDF | View/Open |
Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.