Title: Experimental evaluation of adaptive maximum power point tracking for a standalone photovoltaic system
Authors: Anya, I
Saha, C
Ahmed, H
Rajbhandari, S
Huda, N
Mumtaz, A
Keywords: solar;perturb and observe (P&O);photovoltaic (PV);incremental conductance (IC);MPPT
Issue Date: 18-Apr-2021
Publisher: Springer Nature
Citation: Anya, I. et al. (2022) 'Experimental evaluation of adaptive maximum power point tracking for a standalone photovoltaic system', Energy Systems, 13 (3), pp. 835 - 853. doi: 10.1007/s12667-021-00436-w.
Abstract: The adaptability of maximum power point tracking (MPPT) of a solar PV system is important for integration to a microgrid. Depending on what fixed step-size the MPPT controller implements, there is an impact on settling time to reach the maximum power point (MPP) and the steady state operation for conventional tracking techniques. This paper presents experimental results of an adaptive tracking technique based on Perturb and Observe (P&O) and Incremental Conductance (IC) for standalone Photovoltaic (PV) systems under uniform irradiance and partial shading conditions. Analysis and verification of measured and MATLAB/Simulink simulation results have been carried out. The adaptive tracking technique splits the operational region of the solar PV’s power–voltage characteristic curve into four and six operational sectors to understand the MPP response and stability of the technique. By implementing more step-sizes at sector locations based on the distance of the sector from the MPP, the challenges associated with fixed step-size is improved on.The measured and simulation results clearly indicate that the proposed system tracks MPP faster and displays better steady state operation than conventional system. The proposed system’s tracking efficiency is over 10% greater than the conventional system for all techniques. The proposed system has been under partial shading condition has been and it outperforms other techniques with the GMPP achieved in 0.9 s which is better than conventional techniques.
URI: https://bura.brunel.ac.uk/handle/2438/27450
DOI: https://doi.org/10.1007/s12667-021-00436-w
ISSN: 1868-3967
Other Identifiers: ORCID iD: Ihechiluru Anya https://orcid.org/0000-0002-6991-1940
ORCID iD: Nazmul Huda https://orcid.org/0000-0002-5376-881X
Appears in Collections:Dept of Electronic and Electrical Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2021. This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use (https://www.springernature.com/gp/open-research/policies/journal-policies), but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: https://doi.org/10.1007/s12667-021-00436-w.1.79 MBAdobe PDFView/Open