Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/31945
Title: Experimental Study on the Feasibility of Disassembling and Reusing Lightweight Façade Wall Systems
Authors: Iuorio, O
Kitayama, S
Keywords: building science;lightweight structures;reuse;design for disassembly;cold-formed steel;experiment
Issue Date: 9-May-2024
Publisher: Springer
Citation: Iuorio, O. and Kitayama, S. (2024) 'Experimental Study on the Feasibility of Disassembling and Reusing Lightweight Façade Wall Systems',in V. Ungureanu et al. (eds.) 24th International Conference "Coordinating Engineering for Sustainability and Resilience" & Midterm Conference of CircularB “Implementation of Circular Economy in the Built Environment”. CESARE 2024, (Lecture Notes in Civil Engineering (LNCE) vol. 489). Cham: Springer, pp. 253 - 261. doi: 10.1007/978-3-031-57800-7_23.
Abstract: This paper presents experimental investigations into the feasibility of disassembling and reusing exterior lightweight infill walls. The work stems as necessary steps towards the advancement of circular economy principles in future constructions. The experiment employed the single-shear test method commonly used to assess the shear strength of steel connections. The test samples consisted of cold-formed steel plates attached to hot-rolled steel plates, connected by screws. The cold-formed steel plate represents the track, a component of exterior lightweight infill walls, while the hot-rolled steel plate represents the beams of the primary structural frame. In total, twenty-one specimens were made: nine were tested after screwing, nine were tested after unscrewing and re-screwing, and three were tested after unscrewing, re-screwing, unscrewing, and re-screwing. The unscrewing step demonstrates the disassembly of the infill walls, while the re-screwing demonstrates their reuse. The experimental results revealed that the average peak strengths of the samples with different connections exhibited negligible differences. This can be attributed to the interaction between the screws and the connected cold-formed steel and hot-rolled steel plates, a mechanism further discussed in this paper. The test outcomes imply that exterior lightweight infill walls can be disassembled from the primary structural frame’s beams after the infill walls’ service life, and subsequently reused in the construction of other exterior lightweight infill walls. The study also demonstrated that more specimens should be tested to confirm the observation.
URI: https://bura.brunel.ac.uk/handle/2438/31945
DOI: https://doi.org/10.1007/978-3-031-57800-7_23
ISBN: 978-3-031-57799-4 (pbk)
978-3-031-57800-7 (ebk)
ISSN: 2366-2557
Other Identifiers: ORCiD: Ornella Iuorio https://orcid.org/0000-0003-0464-296X
ORCiD: Shoma Kitayama https://orcid.org/0000-0003-0464-296X
Chapter 23
Appears in Collections:Dept of Civil and Environmental Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © 2024 The Author(s). Rights and permissions: Open Access. This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made. The images or other third party material in this chapter are included in the chapter's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.3.33 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons