Please use this identifier to cite or link to this item: https://bura.brunel.ac.uk/handle/2438/34203
Full metadata record
DC FieldValueLanguage
dc.contributor.authorShamekhi, Shahrbanoo-
dc.contributor.authorHosseini, Vahid-
dc.contributor.authorAl-Zaili, Jafar-
dc.contributor.authorAbmreen, Tehmina-
dc.contributor.authorSayma, Abdulnaser-
dc.date.accessioned2026-11-19T10:23:13Z-
dc.date.available2026-11-19T10:23:13Z-
dc.date.issued2026-11-16-
dc.identifier.citationShamekhi, S. et al. (2026) 'Multi-objective optimisation of start-up scheduling for solar-only Micro gas turbine systems', Applied Thermal Engineering, 310, 134017, pp. 1–23. doi: 10.1016/j.applthermaleng.2026.134017.en_GB
dc.identifier.issn1359-4311-
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/34203-
dc.descriptionData availability: Data will be made available on request.en_GB
dc.description.abstractSolar-only concentrated solar power micro gas turbine (CSP-MGT) systems face unique start-up challenges arising from coupled electro-thermo-mechanical interactions, including compressor surge risk, receiver thermal inertia, and electrical drive constraints, without the benefit of fuel-based regulation. This study presents a multi-objective optimisation framework for start-up scheduling of a 6 kWe parabolic dish CSP-MGT system, based on a validated transient electro-thermo-mechanical model verified against experimental data from the OMSoP project. A three-stage speed schedule is proposed and optimised using NSGA-II across direct normal irradiance (DNI) levels from 300 to 900 W/m2 and for both warm and cold start-up conditions. A two-stage optimisation procedure first determines the minimum starter capacity for off-grid operation, yielding a recommended design value of 2.5 kWe, then resolves the trade-off between start-up duration and motoring energy consumption. Optimised schedules reduce start-up energy by 30–60% relative to the reference procedure across all DNI levels. Annual simulations using site-specific data from Casaccia, Italy confirm that start-up losses are reduced from 7% to 3% of total annual generation, yielding a 5.3% increase in net electricity output. The framework provides a transferable methodology for start-up optimisation of thermally driven micro power systems.en_GB
dc.description.sponsorshipCity St George's, University of London Doctoral Scholarshipen_GB
dc.format.extentpp. 1-23-
dc.languageEnglish-
dc.language.isoenen_GB
dc.publisherElsevieren_GB
dc.rightsRe-use licence for this version: CC BY-
dc.rightsLicence for published version: CC BY-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectsolar MGTen_GB
dc.subjectstart-upen_GB
dc.subjecttransienten_GB
dc.subjectmulti-objective optimisationen_GB
dc.subjectannual performanceen_GB
dc.subject.classification0913 Mechanical Engineering-
dc.subject.classification0915 Interdisciplinary Engineering-
dc.subject.otherEnergy-
dc.titleMulti-objective optimisation of start-up scheduling for solar-only Micro gas turbine systemsen_GB
dc.typeArticleen_GB
dc.identifier.doihttps://doi.org/10.1016/j.applthermaleng.2026.134017-
dc.relation.isPartOfApplied Thermal Engineering-
pubs.publication-statusPublished-
pubs.volume310-
dc.identifier.eissn1873-5606-
dcterms.dateAccepted2026-11-08-
dcterms.descriptionHighlights: • A validated transient electro-thermo-mechanical model for solar-only CSP–MGT start-up. • Multi-objective optimisation of start-up speed schedules for solar-only MGT systems. • Optimised multi-stage schedules reduce start-up energy and time by up to 60%. • Annual simulations show start-up losses reduced from ~7% to ~3% of total generation, resulted in ~5% increase in annual power generation.en_GB
dcterms.issued2026-11-16-
dc.date.updated2026-11-19T10:18:49Z-
dc.contributor.orcidSayma, Abdulnaser [0000-0003-2315-0004]-
dc.identifier.number134017-
Appears in Collections:Department of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © 2026 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license ( https://creativecommons.org/licenses/by/4.0/ ).14.01 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons