Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/6733
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYang, Y-
dc.contributor.authorMorini, GL-
dc.contributor.authorChalabi, H-
dc.contributor.authorLorenzini, M-
dc.contributor.author3rd Micro and Nano Flows Conference (MNF2011)-
dc.date.accessioned2012-09-24T15:31:13Z-
dc.date.available2012-09-24T15:31:13Z-
dc.date.issued2011-
dc.identifier.citation3rd Micro and Nano Flows Conference, Thessaloniki, Greece, 22-24 August 2011en_US
dc.identifier.isbn978-1-902316-98-7-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/6733-
dc.descriptionThis paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, Aristotle University of Thessaloniki, University of Thessaly, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute.en_US
dc.description.abstractThe characteristics of nitrogen convective heat transfer through commercial stainless steel microtubes with inner diameter of 172 μm and 750 μm are investigated both experimentally and numerically. In this work is highlighted that the axial local gas bulk temperature distribution can present a strong nonlinearity along the flow direction especially for microtubes having a small inner diameter and a thick solid wall. It is also demonstrated that the trend of the experimental Nusselt numbers as a function of the Reynolds number can be considered in good agreement with the conventional correlations if the average bulk temperature is calculated by taking into account the axial non-linearity of the gas bulk temperature. This fact explains the low values of the Nusselt numbers obtained in the previous experimental works appeared in literature where the convective heat transfer for gas flows through microtubes has been investigated assuming the gas bulk temperature distribution between the inlet and the outlet of the microtube as linear without verifying this hypothesis.en_US
dc.description.sponsorshipEuropean Community's Seventh Framework Programme (ITN - FP7/2007-2013) under grant agreement no 215504.en_US
dc.language.isoenen_US
dc.publisherBrunel Universityen_US
dc.subjectMicro flowen_US
dc.subjectConvectionen_US
dc.subjectConjugate heat transferen_US
dc.subjectNusselt numberen_US
dc.titleThe effect on the Nusselt number of the non-linear axial temperature distribution of gas flows through commercial microtubesen_US
dc.typeConference Paperen_US
Appears in Collections:Brunel Institute for Bioengineering (BIB)
The Brunel Collection

Files in This Item:
File Description SizeFormat 
MNF2011.pdf109.46 kBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.