Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/6854
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMahmoud, MM-
dc.contributor.authorKarayiannis, TG-
dc.contributor.authorKenning, DBR-
dc.contributor.author3rd Micro and Nano Flows Conference (MNF2011)-
dc.date.accessioned2012-10-05T09:52:39Z-
dc.date.available2012-10-05T09:52:39Z-
dc.date.issued2011-
dc.identifier.citation3rd Micro and Nano Flows Conference, Thessaloniki, Greece, 22-24 August 2011en_US
dc.identifier.isbn978-1-902316-98-7-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/6854-
dc.descriptionThis paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, Aristotle University of Thessaloniki, University of Thessaly, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute.en_US
dc.descriptionThis article has been made available through the Brunel Open Access Publishing Fund.-
dc.description.abstractThe experimental results of two phase flow boiling pressure drop of R134a in vertical micro diameter stainless steel tubes are presented in this paper. The tests were conducted using four tubes; one tube with an inner diameter of 0.52 mm and 100 mm heated length and three tubes with an inner diameter of 1.1 mm and different heated lengths (150, 300 and 450 mm). Other experimental conditions include: mass flux range of 200 – 500 kg/m2 s, system pressure range of 6 – 10 bar, inlet sub-cooling of about 5K and heat flux range of 1 – 140 kW/m2. The results indicated that the total measured two phase pressure drop increases with increasing mass flux, heat flux (exit quality) and decreasing system pressure and tube inner diameter. The test section heated length was found to have a significant effect on the measured pressure drop per metre length. The total measured two phase pressure drop results were also compared with eighteen macro and micro scale models and correlations.en_US
dc.language.isoenen_US
dc.publisherBrunel Universityen_US
dc.subjectMicro tubesen_US
dc.subjectFlow boilingen_US
dc.subjectPressure dropen_US
dc.titleFlow boiling pressure drop of R134a in micro diameter tubes: Experimental results and assessment of correlationsen_US
dc.typeConference Paperen_US
pubs.organisational-data/Brunel-
pubs.organisational-data/Brunel/Brunel Active Staff-
pubs.organisational-data/Brunel/Brunel Active Staff/School of Engineering & Design-
pubs.organisational-data/Brunel/Brunel Active Staff/School of Engineering & Design/Mechanical Engineering-
pubs.organisational-data/Brunel/University Research Centres and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Engineering and Design - URCs and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Engineering and Design - URCs and Groups/Centre for Energy and Built Environment Research-
Appears in Collections:Brunel Institute for Bioengineering (BIB)
Publications
Mechanical and Aerospace Engineering
Brunel OA Publishing Fund
The Brunel Collection
Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
MNF2011.pdf265.31 kBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.