Title: | Inspection and repair considerations for downtime assessment of seismically isolated buildings |
Authors: | Kitayama, S Morales Moncayo, EA Athanasiou, A |
Keywords: | downtime;seismic isolation;ASCE/SEI 7 standard;inspection;repair;performance evaluation;life-cycle analysis |
Issue Date: | 1-Nov-2022 |
Publisher: | Elsevier |
Citation: | Kitayama, S., Morales Moncayo, E.A. and Athanasiou, A. (2023) 'Inspection and repair considerations for downtime assessment of seismically isolated buildings', Soil Dynamics and Earthquake Engineering, 164 (January 2023), 107618, pp. 1 - 16. doi: 10.1016/j.soildyn.2022.107618. |
Abstract: | Copyright © 2022 The Authors. This paper investigates the seismic downtime of seismically isolated buildings with steel moment or braced frames designed by the procedures of ASCE/SEI 7–16. The seismic isolation systems considered in this study are comprised of triple or double friction pendulum isolation bearings with and without moat walls. The seismic downtime is calculated from the damage to structural components and non-structural components, demolition and collapse of buildings. The downtime components (repair and inspection) are defined, and mathematical expressions are provided for the computation of downtime fragility curves, expected annual downtime, and economic losses due to the expected annual downtime. The procedure is then implemented using the results of nonlinear response history analysis from previous studies by the first author. The study demonstrates that the expected annual downtime of seismically isolated buildings is less than that of the comparable non-isolated buildings regardless of the seismic isolation systems used. Among the cases of seismically isolated buildings studied in this paper, it is found that the most effective structural system to mitigate long downtime is the seismically isolated building with seismic isolators with enhanced sizes and with braced frames that are designed to be minimally compliant with the seismic design requirements of ASCE/SEI 7–16. |
Description: | Data availability: Data will be made available on request. |
URI: | https://bura.brunel.ac.uk/handle/2438/28190 |
DOI: | https://doi.org/10.1016/j.soildyn.2022.107618 |
ISSN: | 0267-7261 |
Other Identifiers: | ORCID iD: Shoma Kitayama https://orcid.org/0000-0001-9416-3772 ORCID iD: Anastasia Athanasiou https://orcid.org/0000-0003-2674-2574 107618 |
Appears in Collections: | Dept of Civil and Environmental Engineering Research Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
FullText.pdf | Copyright © 2022 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/) | 5.39 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License