Please use this identifier to cite or link to this item:
http://bura.brunel.ac.uk/handle/2438/31094
Title: | Experimental investigations of water droplet transient phase changes in flue gas flow in the range of temperatures characteristic of condensing economizer technologies |
Authors: | Miliauskas, G Puida, E Poškas, R Ragaišis, V Paukštaitis, L Jouhara, H Mingilaitė, L |
Keywords: | water droplet;humid gas flow;complex transfer processes;condensation;evaporation;experimental investigation |
Issue Date: | 27-Jun-2022 |
Publisher: | Elsevier |
Citation: | Miliauskas, G. et al. (2022) 'Experimental investigations of water droplet transient phase changes in flue gas flow in the range of temperatures characteristic of condensing economizer technologies', Energy, 256, 124643, pp. 1 - 11. doi: 10.1016/j.energy.2022.124643. |
Abstract: | The heating and phase changes of water droplets in 140 °C air flow humidified up to water vapor volumetric fraction of 0.3 were investigated experimentally in the context of heat recovery from flue gases with condensing economizers. The experiments were performed in experimental set-up, where atmospheric air of certain temperature and humidity passed over a water droplet suspended on thermocouple ball. It was demonstrated that initial temperature of droplet and humidity of gas flow are defining factors in transitional phase changes. However, initial droplet temperature had no effect on the equilibrium evaporation regime. The experiments performed confirmed that humidification of atmospheric air flow causes changes in magnitude of heating and phase change process of water droplets suspended in the air flow. These changes translate into increased temperature of equilibrium evaporation of the droplet, formation of favorable conditions for the condensation regime, and a change in dynamics of the droplet's geometrical parameters in initial stage of phase changes. In additionally humidified air flow, the droplet volume increased by three percent, and evaporation temperature of the droplet increased by 17 °C. Practical recommendations for water injection were produced to ensure optimal heat recovery from wet exhaust gases in a condensing economizer. |
Description: | Data availability: Data will be made available on request. |
URI: | https://bura.brunel.ac.uk/handle/2438/31094 |
DOI: | https://doi.org/10.1016/j.energy.2022.124643 |
ISSN: | 0360-5442 |
Other Identifiers: | ORCiD: Valdas Ragaišis https://orcid.org/0000-0002-0480-6162 ORCiD: Linas Paukštaitis https://orcid.org/0000-0002-2779-1514 ORCiD: Hussam Jouhara https://orcid.org/0000-0002-6910-6116 Article number 124643 |
Appears in Collections: | Dept of Mechanical and Aerospace Engineering Research Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
FullText.pdf | Copyright © 2022 Elsevier Ltd. All rights reserved. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/ (see: https://www.elsevier.com/about/policies/sharing). | 796.01 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License