Please use this identifier to cite or link to this item: https://bura.brunel.ac.uk/handle/2438/33670
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMansell, Stephanie K-
dc.contributor.authorAugustt, Sharon-
dc.contributor.authorGowing, Francesca-
dc.contributor.authorRidout, Deborah-
dc.contributor.authorHilton, Stephen-
dc.contributor.authorKilbride, Cherry-
dc.contributor.authorMain, Eleanor-
dc.contributor.authorSchievano, Silvia-
dc.contributor.authorMandal, Swapna-
dc.date.accessioned2026-08-10T15:16:16Z-
dc.date.available2026-08-10T15:16:16Z-
dc.date.issued2026-06-25-
dc.identifier.citationMansell, S.K. et al. (2026) 'Residual AHI Measurement from PAP Devices Versus Home Polygraphy: A Method Comparison Study Using Real World Data', Respiration, 00(0), pp. 1–21. doi: 10.1159/000553192.en_US
dc.identifier.issn0025-7931-
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/33670-
dc.descriptionData Availability: Statement Data supporting this study cannot be made available due to ethical, legal and commercial reasons. Further enquires can be directed to the corresponding author.en_US
dc.description.abstractIntroduction: Residual apnoea hypopnoea index (AHI) derived from positive airway pressure (PAP) device downloads is frequently used to assess treatment effectiveness in obstructive sleep apnoea (OSA). However, the accuracy of device reported AHI in real‑world settings remains uncertain. This study evaluated the agreement between PAP device derived AHI and AHI measured using home based cardiorespiratory polygraphy. Methods: This secondary analysis of the 3DPiPPIn randomised controlled trial included adults with OSA (AHI ≥15 events/hr) naïve to domiciliary PAP therapy. Participants underwent two‑night home cardiorespiratory polygraphy at three and six months. Residual AHI was obtained from Löwenstein PAP devices via data download. Agreement between methods was assessed using Bland–Altman analysis, intraclass correlation coefficients (ICC), and weighted Kappa. Sensitivity and specificity for detecting inadequate control (AHI ≥7 events/hr) were calculated. The association between average leak and AHI discrepancy was examined using linear regression. Results: Ninety‑eight participants were included. PAP derived AHI values consistently underestimated polygraphy derived AHI across all time points. Agreement was poor, with ICCs of 0.02 at three months and 0.16 at six months, and low diagnostic agreement across severity categories at both three months (K0.10, 95%CI: 0 to 0.26) and six months (K0.09, 95%CI: 0 to 0.28). Bland–Altman plots demonstrated systematic underestimation with wide limits of agreement. Sensitivity for detecting inadequate control was very low at both time points (3 months 12% and 6 months 21%), despite high specificity (97% at 3 months and 95% at 6 months). Higher interface leak was significantly associated with greater underestimation of AHI (three months: slope = 0.45, R² = 0.18, p < 0.0001; six months: slope = 0.38, R² = 0.14, p < 0.0001). Conclusion: PAP device downloads substantially underestimated residual AHI and demonstrated poor agreement with home cardiorespiratory polygraphy. These findings highlight important limitations of device derived AHI in real‑world practice, particularly in the presence of interface leak. Where treatment adequacy is uncertain, confirmatory assessment with polygraphy remains necessary.en_US
dc.description.sponsorshipThis project is funded by the NIHR Doctoral Fellowship (NIHR award: 302337).en_US
dc.format.extentpp. 1–21-
dc.format.mediumPrint-Electronic-
dc.languageEnglishen_GB
dc.language.isoenen_GB
dc.publisherS. Kargeren_GB
dc.rightsRe-use licence for this version: CC BY-
dc.rightsLicence for published version: CC BY-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subject1102 Cardiorespiratory Medicine and Haematologyen_GB
dc.subjectRespiratory Systemen_GB
dc.subjectObstructive Sleep Apnoeaen_GB
dc.subjectApnoea Hypopnoea Indexen_GB
dc.subjectPositive Airway Pressure Therapyen_GB
dc.subjectTelemonitoringen_GB
dc.titleResidual AHI Measurement from PAP Devices Versus Home Polygraphy: A Method Comparison Study Using Real World Dataen_GB
dc.typeArticleen_GB
dc.date.dateAccepted2026-06-10-
dc.identifier.doihttps://doi.org/10.1159/000553192-
dc.relation.isPartOfRespirationen_GB
pubs.issue0-
pubs.publication-statusPublished online-
pubs.volume00-
dc.identifier.eissn1423-0356-
dc.rights.licensehttps://creativecommons.org/licenses/by/4.0/legalcode.en-
dcterms.dateAccepted2026-06-10-
dcterms.issued2026-06-25-
dc.date.updated2026-08-10T15:06:44Z-
dc.rights.holderThe Author(s)-
dc.contributor.orcidMansell, Stephanie K. [0000-0002-2806-380X]-
dc.contributor.orcidKilbride, Cherry [0000-0002-2045-1883]-
dc.contributor.orcidMain, Eleanor [0000-0002-9739-3167]-
Appears in Collections:Department of Health Sciences Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © 2026 The Author(s). Published by S. Karger AG, Basel This article is licensed under the Creative Commons Attribution 4.0 International License https://creativecommons.org/licenses/by/4.0 (CC BY). Usage, derivative works and distribution are permitted provided that proper credit is given to the author and the original publisher.3.53 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons