Title: The use of smartphone photogrammetry to digitise transtibial sockets: Optimisation of method and quantitative evaluation of suitability
Authors: Cullen, S
Mackay, R
Mohagheghi, A
Du, X
Keywords: lower limb prosthesis;socket;CAD-CAM;photogrammetry;genetic algorithms;scanning;digital twin;measurement techniques
Issue Date: 16-Dec-2021
Publisher: MDPI
Citation: Cullen, S. et al. (2021) ‘The Use of Smartphone Photogrammetry to Digitise Transtibial Sockets: Optimisation of Method and Quantitative Evaluation of Suitability’, Sensors, 21 (24), 8405, pp. 1 - 16. doi: 10.3390/s21248405.
Abstract: The fit of a lower limb prosthetic socket is critical for user comfort and the quality of life of lower limb amputees. Sockets are conventionally produced using hand-crafted patient-based casting techniques. Modern digital techniques offer a host of advantages to the process and ultimately lead to improving the lives of amputees. However, commercially available scanning equipment required is often expensive and proprietary. Smartphone photogrammetry could offer a low cost alternative, but there is no widely accepted imaging technique for prosthetic socket digitisation. Therefore, this paper aims to determine an optimal imaging technique for whole socket photogrammetry and evaluate the resultant scan measurement accuracy. A 3D printed transtibial socket was produced to create digital and physical twins, as reference models. The printed socket was photographed from 360 positions and simplified genetic algorithms were used to design a series of experiments, whereby a collection of photos were processed using Autodesk ReCap. The most fit technique was used to assess accuracy. The accuracy of the socket wall volume, surface area and height were 61.63%, 99.61% and 99.90%, respectively, when compared to the digital reference model. The scanned model had a wall thickness ranging from 2.075 mm at the top to 7.758 mm towards the base of the socket, compared to a consistent thickness of 2.025 mm in the control model. The technique selected did not show sufficient accuracy for clinical application due to the degradation of accuracy nearer to the base of the socket interior. However, using an internal wall thickness estimation, scans may be of sufficient accuracy for clinical use; assuming a uniform wall thickness.
URI: https://bura.brunel.ac.uk/handle/2438/24013
DOI: https://doi.org/10.3390/s21248405
Other Identifiers: ORCiD: Sean Cullen https://orcid.org/0000-0002-9515-9000
ORCiD: Ruth Mackay https://orcid.org/0000-0002-6456-6914
ORCiD: Amir Mohagheghi https://orcid.org/0000-0003-4295-3718
ORCiD: Xinli Du https://orcid.org/0000-0003-2604-0804
8405
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This is an open access article distributed under the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.3.12 MBAdobe PDFView/Open