Please use this identifier to cite or link to this item:
https://bura.brunel.ac.uk/handle/2438/33876| Title: | Towards Sustainable Concrete Infrastructure: Durability of Full-Scale BFRP Dowel Bars Under Seawater and Alkaline Exposure |
| Authors: | Kamel, Kamel T Shamass, Rabee Zhou, Xiangming Al-Noaimat, Yazeed A Howkins, Ashley Shamseldein, Ayman |
| Keywords: | BFRP dowel bars;durability;marine environment;alkaline exposure;degradation mechanisms |
| Issue Date: | 25-Aug-2026 |
| Publisher: | MDPI |
| Citation: | Kamel, K.T. et al. (2026) 'Towards Sustainable Concrete Infrastructure: Durability of Full-Scale BFRP Dowel Bars Under Seawater and Alkaline Exposure', Buildings, 16(17), 3393, pp. 1–23. doi: 10.3390/buildings16173393. |
| Abstract: | Basalt fibre-reinforced polymer (BFRP) dowel bars offer a corrosion-resistant alternative to steel dowels for jointed concrete infrastructure, particularly in aggressive marine environments. However, the durability of full-scale BFRP dowels remains insufficiently understood because their shear-dominated behavior differs from that of conventional small-diameter FRP reinforcement. This study investigates the durability of 25-mm epoxy-based BFRP dowel bars exposed separately to artificial seawater and alkaline solution at 60 °C under accelerated continuous-immersion conditions. Mechanical performance was evaluated through flexural strength, transverse shear strength, and interlaminar shear strength (ILSS), while chemical and microstructural changes were examined using Fourier-transform infrared spectroscopy (FTIR) and scanning electron microscopy coupled with energy-dispersive spectroscopy (SEM/EDS). At the common 2- and 4-week exposure durations, seawater caused greater flexural-strength losses (10.0% and 11.5%) than alkaline exposure (1.3% and 8.5%), whereas alkaline exposure caused greater reductions in transverse shear strength (7.3% and 8.3% vs. 2.5% and 5.5%) and ILSS (7.0% and 10.0% vs. 1.3% and 2.4%). FTIR and SEM/EDS observations provided complementary evidence of matrix modification and fibre–matrix interfacial deterioration. Overall, the investigated BFRP dowel system showed limited mechanical degradation under the accelerated conditions, indicating promising material-level durability performance within the investigated exposure durations. |
| Description: | Data Availability Statement: The original contributions presented in this study are included in the article; further inquiries can be directed to the corresponding author. |
| URI: | https://bura.brunel.ac.uk/handle/2438/33876 |
| DOI: | https://doi.org/10.3390/buildings16173393 |
| Appears in Collections: | Department of Civil and Environmental Engineering Research Papers |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| FullText.pdf | Copyright © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license. | 17.73 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License